Overview
The ramp test produces the R ratings seen on flooring data sheets, from R9 to R13. A person walks on a sample of the floor while it is tilted, and the angle at which they slip sets the class.
What the test measures
The test finds the steepest angle at which a person can walk safely on an oiled sample of the surface. That angle is called the acceptance angle.
How the test is carried out
The method is DIN 51130, which now sits in EN 16165.
- A sample of the floor is fixed to a platform that can be tilted.
- The surface is coated with oil.
- A tester wearing safety footwear and a harness walks forwards and backwards on it.
- The platform is tilted in steps until the tester slips.
- The result is corrected against reference surfaces, so one tester's gait does not decide the class.
How to read the result
| Class | Acceptance angle |
|---|---|
| R9 | 6° to 10° |
| R10 | Over 10°, up to 19° |
| R11 | Over 19°, up to 27° |
| R12 | Over 27°, up to 35° |
| R13 | Over 35° |
The scale starts at R9. There is no R1 to R8. R9 is therefore the lowest class of slip resistance, and a surface below 6° gets no class at all.
The bands are wide. Two floors at opposite ends of R10 differ by almost nine degrees and share one rating.
What it means in use
R ratings were developed for workplaces where the floor is contaminated with oil or grease and people wear cleated safety boots. They are widely used to specify floors for workshops, commercial kitchens and food production.
What the result does not tell you
The ramp test is a laboratory test. It cannot be carried out on a floor once it is laid, so it cannot confirm how an installed floor performs or how it has worn.
It uses oil and cleated boots. That is not the same condition as a member of the public in ordinary shoes on a wet floor.
An R rating cannot be converted to a pendulum value. In the UK, HSE guidance is built around the pendulum test, so an R rating is best read alongside a PTV. See Slip Resistance (Pendulum Test).
On our product pages
Where a product has been tested, its page shows the result, the method and, where the method has one, the rating. Results published on this site come from internal testing to the stated method. They are given for technical reference and comparison.
If a figure you need is not shown, ask our technical team.



Share:
Water Permeability (Capillary absorption)
Adhesion (Pull-Off)